GenCore UPS Systems — Power Protection Made Simple for Every Application

From a single rack UPS to a fully modular power infrastructure, we help you find the right solution in minutes — not weeks. Our engineers are here to guide you through every step.

ISO 9001 Certified CE & UL Listed 52 Countries Served
380+ Engineers & Staff
52 Countries Served
20+ Years of Experience
99.99% Uptime Rated

Find Your Power Protection Solution

Whether you need a compact rack UPS or an enterprise-grade modular system, our product range covers every power rating and application scenario.

Online UPS Systems

Online UPS Systems

Double-conversion topology delivering zero transfer time and pure sine wave output. From 1kVA to 800kVA for mission-critical loads.

Request Info
Modular UPS Solutions

Modular UPS Solutions

Scale as you grow with hot-swappable modules. N+1 redundancy and pay-as-you-grow architecture from 20kVA to 1.2MVA.

Request Info
DC Power Supplies

DC Power Supplies

Switching and linear DC supplies for industrial automation, telecom, and process control. 12V to 48V output, DIN-rail and rack-mount options.

Request Info

Efficiency That Pays for Itself

Our UPS systems achieve up to 97% AC-AC efficiency in double-conversion mode and 99% in eco-mode, directly reducing your electricity costs and carbon footprint. Active power factor correction (PF > 0.99) minimizes reactive power charges on your utility bill.

  • Up to 97% efficiency in online mode — among the highest in the industry
  • Active PFC achieves PF > 0.99, reducing reactive power penalties
  • ENERGY STAR certified models available across our product range
  • Typical ROI payback period of 24-36 months through energy savings
GenCore UPS energy efficiency monitoring dashboard

Trusted Across Industries

From the server room to the factory floor, GenCore UPS systems protect the applications you depend on most.

Data Centers

Data Centers

Manufacturing

Manufacturing

Healthcare

Healthcare

Telecommunications

Telecommunications

What Our Customers Say

Frequently Asked Questions

Quick answers to the most common questions our customers ask when selecting a UPS system.

What is the difference between online and line-interactive UPS?

An online (double-conversion) UPS continuously converts incoming AC to DC and back to AC, providing zero transfer time and complete isolation from mains disturbances. A line-interactive UPS uses an autotransformer to regulate voltage with a typical 2-4ms transfer to battery. Online UPS is recommended for mission-critical loads like servers, medical equipment, and industrial control systems.

How do I size a UPS for my facility?

Start by calculating your total connected load in kVA or kW. Add a 20-30% headroom for future growth and inrush currents. Consider your required battery runtime (typically 5-30 minutes) and whether you need N+1 redundancy. Our engineers can perform a free load assessment to recommend the optimal configuration.

What certifications do GenCore UPS systems carry?

All GenCore UPS systems are CE marked, UL listed, and manufactured in ISO 9001 certified facilities. Depending on the model, additional certifications include ENERGY STAR, RoHS compliance, and IEC 62040 type-testing. Complete compliance documentation is available on request.

How often should UPS batteries be replaced?

VRLA (valve-regulated lead-acid) batteries typically last 3-5 years depending on ambient temperature and discharge cycles. Lithium-ion batteries can last 8-10 years. We recommend annual battery health checks and offer proactive replacement programs to prevent unexpected failures.

Can GenCore UPS systems be monitored remotely?

Yes. All our UPS models above 3kVA include SNMP/Modbus TCP network management interfaces as standard. Our optional cloud monitoring platform provides real-time status dashboards, automated alerts, and historical performance analytics accessible from any device.

Do you provide on-site installation and commissioning?

Absolutely. Our factory-trained service engineers are available in 52 countries for on-site installation, commissioning, load-bank testing, and staff training. We also offer preventive maintenance contracts and 24/7 emergency response for critical installations.

Not Sure Which UPS Is Right for You?

Our power engineers will analyze your requirements and recommend the optimal solution — completely free of charge. No pressure, just expert advice.

  • Free load assessment and UPS sizing
  • Product recommendations within 24 hours
  • Complete documentation package included
  • No obligation — just honest guidance

Get Your Free Consultation